Description
CATL EnerD is a 4.472MWh liquid-cooled containerised battery energy-storage system designed for utility, generation-side, grid-side and large commercial or industrial projects. It combines CATL 280Ah LiFePO4 cells, 46.59kWh liquid-cooled battery boxes and high-voltage battery clusters in a project-scale enclosure.
LiFePO4 Australia sources genuine new CATL equipment through eligible partner factories and wholesale partners. This controlled supply route is designed to keep B-grade, used, reconditioned and rewrapped cells out of our CATL supply chain.
Project-scale energy storage
- 4.472MWh nominal energy and 4.472MW rated charge/discharge power
- CATL 280Ah LiFePO4 cells in liquid-cooled 46.59kWh battery boxes
- 1331.2V DC nominal system voltage with a 1040–1500V cluster range
- IP55 container, C4 corrosion class and liquid cooling
- CAN, RS485 and LAN communications with IEC 61850 support listed by the manufacturer
Engineered supply only
EnerD is large-scale project equipment and requires a complete engineering and compliance scope. PCS, transformer, switchgear, fire systems, site works, grid connection, transport, cranage, installation and commissioning are not assumed to be included unless they appear in the final project quotation. Contact our team to discuss system architecture, availability and commercial pricing.
Specifications
| Brand / model | CATL EnerD |
|---|---|
| Nominal energy | 4.472MWh |
| Rated charge/discharge power | 4.472MW |
| Rated charge/discharge rate | 1P |
| System configuration | 12P × (1P52S × 8S) |
| Nominal voltage | 1331.2V DC |
| Dimensions | 6590 × 2550 × 3000mm |
| Weight | Approximately 41.5 tonnes |
| Cell capacity / energy | 280Ah / 896Wh |
| Cell operating voltage | 2.5–3.65V DC |
| Battery box | 1P52S, 46.59kWh, 166.4V DC |
| Battery cluster | 1P52S × 8S, 372.73kWh, 1331.2V |
| Cluster voltage range | 1040–1500V |
| Cooling | Liquid cooled |
| Communications | CAN / RS485 and LAN (IEC 61850) |
| IP rating | IP55 |
| Corrosion class | C4 |
| Working temperature | -30 to 60°C |
| Storage temperature | -30 to 60°C |
| Maximum operating humidity | 90% |
| Maximum operating altitude | 4000m |
| Auxiliary power | 380V AC ±15% at 50Hz; 125kW maximum |
| Manufacturer-listed standards | GB/T 34131 and GB/T 36276 |
| Availability | Engineered project enquiry / coming soon |