Victron Multi RS Solar 48v 6000w + 15.67Kwh 10000 Cycle Lifepo4 Battery Bundle

Original price was: $10,229.00.Current price is: $8,799.00.

Original price was: $3,230.00.Current price is: $2,800.00.
MASSIVE PRE-ORDER PRICE DISCOUNT EXTENDED SAVE $1000 EXTENDED Australias Best Value High Quality Premium LiFePO4 Battery
Original price was: $6,999.00.Current price is: $5,999.00.
Delivery to a nearby Depot or Commercial Address included
6 left in stock

Description

Victron Multi RS Solar 48v 6000w + 15.67Kwh 10000 Cycle Lifepo4 Battery Bundle

Bundle Includes:

1 x Victron Multi RS Solar 48V 6000W 450-100 Dual Tracking Inverter/Charger/Regulator  PMR482602020 Inverter (High Efficiency Model)

    • Peak Power: Up to 12,000W (for short durations)
    • Continuous Output Power: 6,000 VA (4,800 W) at 25 Celcius
    • The inverter can handle short bursts of up to 12000 Watts for high load demand, useful for appliances like pumps or motors that need extra power during startup.
  • 1 x 15.67kWh LiFePO4 Battery
    • Includes 200A BMS and a 250A DC Circuit Breaker
    • Features huge 2A active balancer to keep your battery working longer
    • Includes Bluetooth, CAN, RS485
    • A+ Tier 1 Grade MB30 306AH cells (real capacity ~330Ah)

Versatile Operating Modes for Every Need

  • Hybrid Mode: Harness solar power to its fullest by storing excess energy in a battery for use at night or during peak demand, with the ability to supplement power from the battery when consumption exceeds grid capacity.
  • Backup Mode: Experience uninterrupted power with an automatic switch to backup during grid outages, keeping your critical systems running smoothly.
  • Off-Grid Mode: Gain complete independence with the ability to operate without any grid connection, perfect for remote locations.
  • Generator Mode: Optimize generator use by controlling run-hours and supplementing with battery power when demand outstrips generator capacity.

Advanced PowerControl and PowerAssist Features

Set maximum currents for your grid or generator to prevent overloads with the PowerControl function. The Multi RS Solar takes it a step further with PowerAssist, supplementing insufficient power with battery reserves during peak demand and recharging the battery when the load decreases.

Dual MPPT for Maximum Solar Harvesting

With dual MPPT, the Multi RS Solar 48/6000 ensures that you’re capturing the maximum energy from your solar panels, even in varying lighting conditions. This feature allows for two independent solar arrays, optimizing energy harvest and providing redundancy.

Intuitive Monitoring with Display, Bluetooth, and VictronConnect App

Keep a close eye on your system’s health with the integrated display showing battery, inverter, and solar parameters. For remote monitoring and control, the VictronConnect app pairs seamlessly with your device via Bluetooth.

Scalable PV Capacity

Your solar capacity grows with you. Start with the integrated 6 kWp PV capacity and expand by adding solar chargers for AC or DC coupling. Integrate additional PV Inverters with automatic power control for a tailored energy solution.

Robust Communication and Connection Options

Monitor, log data, and update firmware remotely via VE.Can connection to a GX device. For remote monitoring, connect with VE.Direct to a GlobalLink 520. Programmable relays, temperature sensors, and voltage sensors ensure a customizable and secure setup.

The Victron Multi RS Solar 48/6000 Dual Tracker is not just an inverter/charger—it’s the heart of your solar energy system. It’s designed to adapt to your changing power needs while providing efficiency and reliability. Step into the future of energy management and make the smart move to a system that grows with your energy demands.

IMPORTANT THIS INVERTER DOES NOT SUPPORT PARALLEL – 3-phase and parallel operation : 3-phase support with one unit per phase.

51.2V 306Ah 15.67kwh EVE 8000 cycles LiFePo4 Battery

Using the newest generation 314ah capacity MB30 cells from EVE Energy, this battery is the ultimate in value.

Featuring the latest and greatest inverter support BMS from JK BMS, you can rest assured you have the absolute best battery on the market today, especially if you have Victron, DEYE or Growatt Inverters. The 3 most popular off grid solutions in Australia.

Battery Features

  • EVE MB30 306AH 8000 Cycle Cells tested at over 330AH
  • BMS 200A 2A active Balancer to ensure long life and high current balancing of your cells
  • 250A DC Circuit Breaker
  • Heavy Duty Castor Wheels
  • Weight 110kg

Compatible with Victron & Growatt Inverters

LiFePO4 Lithium Battery Pack Spec
Model No LIFEPRO15.67Kwh
Nominal Parameters
Voltage 51.2V
Capacity 306Ah (when new ~330Ah)
Energy 15.67Kwh
Dimensions (L*W*H) 585 x 610 x 217mm
Weight 110kg
Basic Parameters
Expected Lifespan (25℃) 10-15 Years of daily use.
Life cycles (80%DOD,25℃) 10000 times
Storage time/ temperature 5 months @25℃; 3 months @35℃; 1 months @45℃;
Operation temperature -20℃ to 60℃ @60+/-25% Relative Humidity
Charging temperature 0℃ to 45℃ @60+/-25% Relative Humidity
Lithium Battery
Enclosure protection rating IP21
Electrical Parameters
Operation voltage 46-58.4Vdc
Max.charging voltage 58.4Vdc
Max.charging and discharging current 200A
Max.charging and discharging Watts 10000

 

Additional information

Weight 130 kg
Dimensions 70 × 80 × 50 cm

ModelMulti RS Solar 48/6000 Dual Tracker
PowerControl & PowerAssistYes
Transfer switch50 A
Maximum AC input and pass-through current50 A
INVERTER 
DC Input voltage range (1)38 – 62 V
AC Output (2)Output voltage: 230 VAC ± 2 %
Frequency: 50 Hz ± 0,1 %
Maximum continuous inverter current: 25 Aac
Continuous output power at 25 °CIncreases linearly from 4800 W at 46 VDC
to 5300 W at 52 VDC
Continuous output power at 40 °C4500 W
Continuous output power at 65 °C3000 W
Peak power (3)9 kW for 3 seconds
7 kW for 4 minutes
Short-circuit output current45 A
Max. AC output overcurrent protection30 A
Efficiency96.5 % at 1 kW load
94 % at 5 kW load
Zero load power consumption20 W
Low Battery shutdown37.2 V (adjustable)
Low battery restart43.6 V (adjustable)
SOLAR 
Maximum open circuit PV array voltage^{(4)}450 V
Start-up voltage120 V
MPPT operating voltage range80 – 450 V
Maximum operational PV input current limit13 A
Maximum PV conversion power6 kW total – 3 kW per tracker
Maximum PV short circuit current16 A
Earth leakage trip level30 mA
Isolation fail level (detection before start-up)100 kΩ
CHARGER 
AC InputNominal Voltage: 230 VAC, Input voltage range: 187-265 VAC
Nominal frequency: 50 Hz, Input frequency: 45-65 Hz
AC inrush current: NA
Programmable charge voltage range (5)36 – 60 V
Charge voltage 'absorption'Default setting: 57.6 V (adjustable)
Charge voltage 'float'Default setting: 55.2 V (adjustable)
Maximum charge current from AC (6)88 A @ 57.6 VDC
Total maximum charge current (AC + PV)100 A DC
Battery temperature sensorIncluded
Battery voltage senseYes
GENERAL 
Auxiliary output (AC-out-2) (7)Yes
3-phase and parallel operation3-phase support with one unit per phase. Parallel not supported.
Programmable relay (8)Yes
Protections (9)a - g
Data communications ports (10)VE.Direct, VE.Can & Bluetooth
Bluetooth frequency & power2402 - 2480 Mhz, 4 dBm
Programmable analog/digital input/output portsYes, 2x
Remote on-offYes
Operating temperature range-40 to +65 °C (fan assisted cooling)
Maximum altitude2000 m
Humidity (non-condensing)max 95 %
ENCLOSURE 
Material & Coloursteel, blue RAL 5012
Protection categoryIP21 Protective Class: I
Battery-connectionM8 bolts
PV Connection2 strings, each with positive and negative MC4
230 VAC-connectionScrew terminals 10 mm² (6 AWG)
Weight12.3 kg
Dimensions (hxwxd)425 x 460 x 125 mm
STANDARDS 
SafetyEN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2
Emission, ImmunityEN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2,
IEC 61000-6-3, Pollution Degree 2
Overvoltage CategoryBattery: OVC 1, PV port: OVC II, AC in / AC out: OVC III
1) Minimum start-up voltage is 41 VDC. Over-voltage disconnect: 65,5 V.
2) Can be adjusted to 240 VAC and 60 Hz
3) Peak power capacity and duration depends on start temperature of heatsink.
Mentioned times are with cold unit.
4) The maximum PV voltage should not exceed 8x battery float voltage.
If for example the float voltage of the battery is 50 V,
the maximum PV voltage should not exceed 8 x 50 = 400 V.
5) The Charger set points (float & absorption) can be set to max 60 V.
The output voltage at the charger terminals can be higher due to compensation
for temperature & voltage drop over the battery cables.
The maximum output current is reduced on a linear basis from full current at 60 V to
5 A at 62 V. The equalization voltage can be set to max 62 V, the equalization current
percentage can be set to max 6 %.
6) The maximum charge current from AC sources depends on input voltage and battery current. At 230V input and 57.6V battery voltage, and 25C ambient, the maximum charge
current is 88 A. See manual, limitations section, for further details.
7) AC-out-2 is connected directly to the AC input and intended for non-critical loads. The AC-out-2 load is taken into account by PowerControl & PowerAssist.
8) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. DC rating: 4 A up to 35 VDC and 1 A up to 70 VDC
9) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) solar
earth leakage.
10) Not currently compatible with VE.Smart Networks. Connection to a GX device (i.e. Cerbo GX) must be made via the VE.Can interface. The VE.Direct interface is for connection to
the GlobalLink 520.

Operating modes
Hybrid mode – Stores excess solar energy in a battery, to be used during the night or periods of high
demand. Supplies additional power from the battery when demand exceeds grid capacity.
Backup mode – Switches to backup mode during a grid outage.
Off-grid mode – Operates without grid connection.
Generator mode – Controls the generator to minimize run-hours. Supplies additional power from the
battery when demand exceeds the capacity of the generator


PowerControl and PowerAssist - Boosting the capacity of the grid or a generator
A maximum grid or generator current can be set. The Multi RS will then take account of other AC loads and
use whatever is extra for battery charging, thus preventing the generator or grid from being overloaded
(PowerControl function).
PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often
required only for a limited period, the Multi RS will compensate insufficient generator or grid power with
power from the battery. When the load reduces, the spare power is used to recharge the battery.


X

We have recently changed our naming of the cell grades. Due to misrepresenatation within the industry.

X

Please enter your email address to receive your cart as a PDF.

Enquiry Cart
Enquiry Cart ×
Loading....